Henan Huatai Special Cable Co., Ltd.

450/750v 600/1000v flexible rubber mining cable

450/750v 600/1000v flexible rubber mining cable
Product Detailed

Application:
Cables are applicable to transmit electric energy for colliery equipments with A.C rated voltage up to 10kV.

1.Rated voltage Uo/U 1.9/3.3KV, 3.6/6KV and 6/10KV
2.Long-term operating temperature of conductor is 90 o C
3.The min. bevelling radius should be 6 times of cable outer diameter

Type

Description

Application

UYPT MYPT-1.9/3.3

Coal mining movable metallic shield rubber sheathed flexible cable

Connected power for movable coal mining equipment rated voltage upto 1.9/3.3KV

UYP MYP-3.6/6

Coal mining movable shield rubber sheathed flexible cable

Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 3.6/6KV,allowed ambient Min.temperature is -20 o C

UYPT MYPT-3.6/6

Coal mining movable metallic shield rubber sheathed flexible cable

 

UYDP MYDP-3.6/6

Coal mining movable shield rubber sheathed flexible cable

Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 3.6/6KV,allowed ambient Min.temperature is -40 o C

UYDPT MYDPT-3.6/6

Coal mining movable metallic shield rubber sheathed flexible cable

 

UYP MYP-6/10

Coal mining movable shield rubber sheathed flexible cable

Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 6/10KV,allowed ambient Min.temperature is -20 o C

UYPT MYPT-6/10

Coal mining movable metallic shield rubber sheathed flexible cable

Connected power for all kinds of movable coal mining equipment on the ground rated voltage upto 6/10KV,allowed ambient Min.temperature is -20 o C

Specification:

NO.ominal cross-section of conductor mm 2

Nominal Thickn mm

Outer diameter of cable mm

Power core

Earthing core

Power core insulation

sheath

UYPT MYPT-1.9/3.3

35

36/3

2.8

6.0

51.5-55.1

30

35/3

2.8

6.0

52.0-56.8

30

35/3

3.0

6.0

56.5-62.1

35

30/3

3.0

6.0

62.0-68.2

 

NO.ominal cross-section of conductor mm 2

Nominal Thickn mm

Outer diameter of cable mm

Power core

Earthing core

Power core insulation

sheath

UYP MYP-3.6/6
UYPT MYPT-3.6/6

36

16

4.0

5.5

50.5-53.0

35

16

4.0

5.5

54.3-59.7

35

16

4.0

5.5

58.5-63.0

30

15

4.0

5.5

62.5-67.7

30

15

4.0

5.5

62.5-71.7

35

10

4.0

5.5

67.5-76.8

32

10

4.0

5.5

70.1-79.8

35

10

4.0

5.5

76.0-86.3



Copyright Notice @ 2008-2022 B2BAGE Limited and/or its subsidiaries and licensors. All rights reserved.