Henan Huatai Special Cable Co., Ltd.

Triplex Aluminum Service Drop Cable

Triplex Aluminum Service Drop Cable
Product Detailed

Service Drop Cable for Power tranmission, used for rebuilding of urban and forest regions.

Product Description:

 

Applications:

To supply power from the utility's lines to the consumer's weatherhead. For service at 600 volts or less (phase to phase) at a conductor temperature of 75°C maximum for polyethylene Insulation or 90°C maximum for crosslinked insulation.

 

Construction:

Concentric strand or compressed 1350-H19 conductor, polyethylene or crosslinked polyethylene insulation, concentric strand AAC, ACSR or 6201 alloy neutral messenger.

Standards:

B-230 Aluminum Wire 1350-H19 for Electrical Purposes

B-231 Aluminum Conductors, Concentric-Lay-Stranded

B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR)

B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors

B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).

Triplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA body S-76-474.

Code Word

Phase Conductor

Bare Neutral Messenger

Weight Per 1000ft. (lbs.)

Allowable Ampacity

Size (AWG)

Strand- ing

Insul. Thick. (mils)

Size (AWG)

Size (kcmil)

Strand- ing

Rated Strength (lbs)

XLP

POLY

XLP

POLY

6201 ALLOY NEUTRAL-MESSENGER

Minex

6

1

45

6

30.58

7

1110

101

101

85

70

Hippa

6

7

45

6

30.58

7

1110

107

107

85

70

Prawn

4

1

45

4

48.69

7

1760

152

152

115

90

Barnacle

4

7

45

4

48.69

7

1760

160

160

115

90

Shrimp

2

7

45

2

77.47

7

2800

243

243

150

120

Gammarus

1/0

7

60

1/0

123.3

7

4460

390

390

205

160

Leda

1/0

9

60

1/0

123.3

7

4460

384

384

205

160

Dungenese

2/0

7

60

2/0

155.4

7

5390

483

483

235

185

Cyclops

2/0

11

60

2/0

155.4

7

5390

474

474

235

185

Flustra

3/0

17

60

3/0

195.7

7

6790

587

587

275

215

Lepas

4/0

18

60

4/0

246.9

7

8560

728

728

315

245

*Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Haiotis/XLP).+Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

 